Safety barrier with M profile fixed at C110 post installed in soil.
Nordic M H1
Arbetsbeskrivning
Ladda ner
Performance
Harmonised standard: EN1317‑5:2007/A2:2012
- Containment level
- Working width (class)
- Impact severity level
- Vehicle intrusion (class)
- Resistance to snow removal
- H1
- W4
- A
- VI5
- 4
- Post spacing (m)
- Working width (m)
- Dynamic defl. (m)
- Construction width (m)
- Construction height (m)
- Durability
- 3.0
- 1.2
- 1.1
- 0.2
- 0.7
- Hot dip galvanized coatings according to SS-EN ISO 1461:2009 National Annex. Fe/Zn 115
- Containment level
- Working width (class)
- Impact severity level
- Vehicle intrusion (class)
- Resistance to snow removal
- H1
- W4
- A
- VI5
- 3.0
- 4
- Post spacing (m)
- Working width (m)
- Dynamic defl. (m)
- Construction width (m)
- Construction height (m)
- 3.0
- 1.2
- 1.1
- 0.2
- 0.7
- Durability:
- Hot dip galvanized coatings according to SS-EN ISO 1461:2009 National Annex. Fe/Zn 115