﻿{"id":1325,"date":"2026-05-27T14:54:30","date_gmt":"2026-05-27T12:54:30","guid":{"rendered":"https:\/\/nordicroadsafety.com\/?page_id=1325"},"modified":"2026-06-15T10:19:20","modified_gmt":"2026-06-15T08:19:20","slug":"control","status":"publish","type":"page","link":"https:\/\/nordicroadsafety.com\/en\/services\/control\/","title":{"rendered":"Control"},"content":{"rendered":"\n<div class=\"wp-block-group is-style-no-padding has-beige-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:0px;padding-bottom:0px\"><div class=\"hero-space-subpage container\">\n\t<div class=\"row\">\n\t\t<div class=\"col-md-6 col-sm-12 col-xs-12\">\n\t\t\t<div class=\"content-container\" data-aos=\"fade-up\">\n\t\t\t\t\t\t\t<div class=\"subtitle\">Inspection Services<\/div>\n\t\t\t\t\t\t\t\t<h1>Technical Expertise<\/h1>\n\t\t\t\t\t\t\t\t<p class=\"preamble\">To guarantee the safety and longevity of various structures, we offer a wide range of specialized inspection services. We work preventively and systematically to ensure that every component meets applicable requirements and standards.<\/p>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t<div class=\"col-md-6 col-sm-12 col-xs-12\">\n\t\t\t\t\t\t\t<figure>\n\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1246\" height=\"918\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10401-1246x918.jpg\" class=\"attachment-hero-space size-hero-space\" alt=\"\" srcset=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10401-1246x918.jpg 1246w, https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10401-939x691.jpg 939w\" sizes=\"(max-width: 1246px) 100vw, 1246px\" title=\"\">\t\t\t\t<\/figure>\n\t\t\t\t\t\t<\/div>\n\t<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-78cc654d wp-block-group-is-layout-constrained\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"imgtext \" data-aos=\"fade-up\">\n\n\t<div class=\"container\">\n\t\t<div class=\"row\">\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\t\t\t\t\t\t\t\t\t<figure>\n\t\t\t\t\t\t<img decoding=\"async\" width=\"939\" height=\"691\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10360-939x691.jpg\" class=\"attachment-imgtext size-imgtext\" alt=\"\" srcset=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10360-939x691.jpg 939w, https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10360-1246x918.jpg 1246w\" sizes=\"(max-width: 939px) 100vw, 939px\" title=\"\">\t\t\t\t\t<\/figure>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\n<div>\n\t\t\t\t\t\t\t\t\t<h2>Welding tests<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d832c6e elementor-widget elementor-widget-text-editor\" data-id=\"d832c6e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<p>Work on pressure equipment and steel structures requires certified personnel.<\/p>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-1734520 elementor-widget elementor-widget-text-editor\" data-id=\"1734520\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<p>Our welding inspector is qualified in welding test supervision and is therefore approved to issue welding test certificates in steel structures and pressure equipment, PED<\/p>\n<p>According to 9606-1 Welding test<br \/>\nAccording to ISO 14732 Testing of welding operators for fully mechanised welding<\/p>\n<\/div>\n<\/div>\n<p><a href=\"https:\/\/www.trkab.se\/svetsarprovning\" target=\"_blank\" rel=\"noopener\"><i>We partner with TRK AB, an organization accredited by SWEDAC according to ISO 17024<\/i><\/a><\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-lighter-blue-background-color has-background is-layout-constrained wp-container-core-group-is-layout-78cc654d wp-block-group-is-layout-constrained\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Non-destructive testing<\/h2>\n\n\n<div class=\"imgtext right\" data-aos=\"fade-up\">\n\n\t<div class=\"container\">\n\t\t<div class=\"row\">\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\t\t\t\t\t\t\t\t\t<figure>\n\t\t\t\t\t\t<img decoding=\"async\" width=\"939\" height=\"691\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10394-939x691.jpg\" class=\"attachment-imgtext size-imgtext\" alt=\"\" srcset=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10394-939x691.jpg 939w, https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS-2026-02-18_10394-1246x918.jpg 1246w\" sizes=\"(max-width: 939px) 100vw, 939px\" title=\"\">\t\t\t\t\t<\/figure>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\n<div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h3>Magnetic particle testing (MT)<\/h3>\n<p>Magnetic particle testing can detect defects in and just below the surface of magnetic materials, and is commonly used for crack detection.<\/p>\n<p>Our inspector is certified according to EN ISO 9712, LEVEL-II<\/p>\n<p><em>Non-accredited service<\/em><\/p>\n<h3><b data-path-to-node=\"1,0\" data-index-in-node=\"0\">Penetrant Testing (PT)<\/b><\/h3>\n<p>Penetrant testing is used to detect cracks and other surface-breaking defects, and is most commonly used on stainless and non-magnetic materials.<\/p>\n<p><em>Non-accredited service<\/em><\/p>\n<h3><b data-path-to-node=\"1,1\" data-index-in-node=\"0\">Visual Testing (VT)<\/b><\/h3>\n<p>Visual testing is used to detect visible surface defects, such as cracks and damage.<\/p>\n<p><em>Non-accredited service<\/em><\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"imgtext \" data-aos=\"fade-up\">\n\n\t<div class=\"container\">\n\t\t<div class=\"row\">\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\t\t\t\t\t\t\t\t\t<figure>\n\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"939\" height=\"691\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/Teknikstod-939x691.jpg\" class=\"attachment-imgtext size-imgtext\" alt=\"\" srcset=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/Teknikstod-939x691.jpg 939w, https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/Teknikstod-1246x918.jpg 1246w\" sizes=\"(max-width: 939px) 100vw, 939px\" title=\"\">\t\t\t\t\t<\/figure>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\n<div>\n\t\t\t\t\t\t\t\t\t<h2>Technical Support \u2013 Steel Structures<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<ul>\n<li>\n<p data-path-to-node=\"1,1,0,0\">Review drawings and technical documentation for steel structures.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,1,0\">Support the construction manager with technical questions regarding steel installation.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,2,0\">Verify that structures comply with applicable standards and requirements.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,3,0\">Coordinate with structural engineers, suppliers, and installers.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,4,0\">Handle technical deviations and propose on-site solutions.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,5,0\">Verify material certificates and quality documentation.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,6,0\">Participate in inspections and quality controls.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,7,0\">Monitor that installation is carried out according to drawings and method statements.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,8,0\">Provide advice on welding, corrosion protection, and fastenings.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"1,1,9,0\">Prepare technical reports and documentation.<\/p>\n<\/li>\n<\/ul>\n\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-lighter-blue-background-color has-background is-layout-constrained wp-container-core-group-is-layout-78cc654d wp-block-group-is-layout-constrained\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"imgtext right\" data-aos=\"fade-up\">\n\n\t<div class=\"container\">\n\t\t<div class=\"row\">\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\t\t\t\t\t\t\t\t\t<figure>\n\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"939\" height=\"691\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS_2021-10-13_0976-939x691.jpg\" class=\"attachment-imgtext size-imgtext\" alt=\"\" srcset=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS_2021-10-13_0976-939x691.jpg 939w, https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/NRS_2021-10-13_0976-1246x918.jpg 1246w\" sizes=\"(max-width: 939px) 100vw, 939px\" title=\"\">\t\t\t\t\t<\/figure>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t<div class=\"col-sm-6 col-xs-12\">\n\n<div>\n\t\t\t\t\t\t\t\t\t<h2>Measurements of contact<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p>We perform RRA measurements (resistance measurements between corrosion protection systems and reinforcement) in bridge structures in accordance with the Swedish Transport Administration&#8217;s requirements and applicable industry standards. These measurements ensure that cast-in bolt groups and other steel components are electrically separated or isolated from the reinforcement within the concrete structure.<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><section class=\"kontakter-block\">\n\n\t\t\t<div class=\"kontakter-block__header\">\n\t\t\t\t\t\t\t<h2 class=\"kontakter-block__title\">Interested in our Inspection Services?<\/h2>\n\t\t\t\t\t\t\t\t\t\t<p class=\"kontakter-block__subtitle\">Get in touch with our specialists in this field to get your questions answered directly<\/p>\n\t\t\t\t\t<\/div>\n\t\n\t\t\t<div class=\"kontakter-block__persons contact-person-block\">\n\t\t\t\t\t\t\t\t<div data-title=\"north-region production warehouse-and-transport\" class=\"contact-person\">\n\n\t\t\t\t\t<figure class=\"contact-person-image\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"439\" height=\"439\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/03\/Tobias-Morsky_11471-439x439.jpg?v=2\" class=\"attachment-contact-person size-contact-person wp-post-image\" alt=\"\" title=\"\">\t\t\t<\/figure>\n\t\t\n\t\t\t\t\t<h3>Tobias M\u00f6rsky<\/h3>\n\t\t\n\t\t<div class=\"contact-person-info\">\n\n\t\t\t\t\t\t\t<div class=\"contact-person-title\">\n\t\t\t\t\tWelding manager\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"contact-person-phone\">\n\t\t\t\t\t<a target=\"\" href=\"tel:+4660144135\">\n\t\t\t\t\t\t+46 60 144 135\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"contact-person-email\">\n\t\t\t\t\t<a target=\"\" href=\"mailto:tobias.morsky@nordicroadsafety.com\">\n\t\t\t\t\t\tEmail me\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\n\n\t\t<\/div>\n\n\t<\/div>\n\t\t\t\t\t\t\t\t\t<div data-title=\"north-region production warehouse-and-transport\" class=\"contact-person\">\n\n\t\t\t\t\t<figure class=\"contact-person-image\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"439\" height=\"439\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/04\/William-Bylund_1398-439x439.jpg?v=2\" class=\"attachment-contact-person size-contact-person wp-post-image\" alt=\"\" title=\"\">\t\t\t<\/figure>\n\t\t\n\t\t\t\t\t<h3>William Bylund<\/h3>\n\t\t\n\t\t<div class=\"contact-person-info\">\n\n\t\t\t\t\t\t\t<div class=\"contact-person-title\">\n\t\t\t\t\tOFP-Technician\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"contact-person-phone\">\n\t\t\t\t\t<a target=\"\" href=\"tel:+4660144144\">\n\t\t\t\t\t\t+46 60 144 144\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"contact-person-email\">\n\t\t\t\t\t<a target=\"\" href=\"mailto:william.bylund@nordicroadsafety.com\">\n\t\t\t\t\t\tEmail me\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\n\n\t\t<\/div>\n\n\t<\/div>\n\t\t\t\t\t\t\t\t\t<div data-title=\"north-region technology-and-product-development\" class=\"contact-person\">\n\n\t\t\t\t\t<figure class=\"contact-person-image\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"439\" height=\"439\" src=\"https:\/\/nordicroadsafety.com\/en\/wp-content\/uploads\/sites\/3\/2026\/06\/Ronny_7510-1-439x439.jpg?v=2\" class=\"attachment-contact-person size-contact-person wp-post-image\" alt=\"\" title=\"\">\t\t\t<\/figure>\n\t\t\n\t\t\t\t\t<h3>Ronny Westlinder<\/h3>\n\t\t\n\t\t<div class=\"contact-person-info\">\n\n\t\t\t\t\t\t\t<div class=\"contact-person-title\">\n\t\t\t\t\tDeveloper and maintenance\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"contact-person-phone\">\n\t\t\t\t\t<a target=\"\" href=\"tel:+4660144144\">\n\t\t\t\t\t\t+46 60 144 144\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"contact-person-email\">\n\t\t\t\t\t<a target=\"\" href=\"mailto:ronny.westlinder@nordicroadsafety.com\">\n\t\t\t\t\t\tEmail me\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\n\n\t\t<\/div>\n\n\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Non-destructive testing<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":25,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_trash_the_other_posts":false,"editor_notices":[],"footnotes":""},"class_list":["post-1325","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/pages\/1325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/comments?post=1325"}],"version-history":[{"count":46,"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/pages\/1325\/revisions"}],"predecessor-version":[{"id":1813,"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/pages\/1325\/revisions\/1813"}],"up":[{"embeddable":true,"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/pages\/25"}],"wp:attachment":[{"href":"https:\/\/nordicroadsafety.com\/en\/wp-json\/wp\/v2\/media?parent=1325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}